Siemens F01700 fault code meaning
Siemens / F01700
Series: G115D
SI Motion P1 (CU): STOP A triggered
converter
Meaning: STOP A stops the drive (STO is executed via the safety shutdown path of processor 1). Possible causes: - Processor 2 issued a stop request. - STO did not take effect after "Forced fault check" was selected. - Subsequent response to message C01711 "SI motion P1 (CU): Monitoring channel error". - Subsequent response to message C01714 "SI motion P1: Safely-Limited Speed exceeded".
Possible causes
Source: SINAMICS G115D P740
Series: G120-CU240B-E-2, G120-CU250S-2
SI Motion P1 (CU): STOP A triggered
converter
Meaning: STOP A stops the drive (pulse suppression via the safety shutdown path of processor 1). Possible causes: - Processor 2 issued a stop request. - Pulses were not suppressed after "Forced fault checking" was selected. - Follow-up reaction to message C01706 "SI Motion P1: SAM/SBR limit exceeded". - Follow-up reaction to message C01714 "SI Motion P1: Safely-Limited Speed exceeded". - Follow-up reaction to message C01701 "SI Motion P1: STOP B triggered".
Possible causes
Source: SINAMICS G120 Control Unit CU240B- 2_CU240E- 2 P819; SINAMICS G120 Control Units CU250S-2 P1032
Series: G120D
SI Motion P1 (CU): STOP A triggered
converter
Meaning:
Possible causes
Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P844
Series: S210
SI Motion P1: STO triggered
servo drive
Meaning: STO causes the drive to stop. Possible causes: - Another monitoring channel has issued a stop request. - After "Forced fault check" was selected, STO did not become active when the set time (p9557) elapsed. - Subsequent response to the following messages: A01706, A01714, F01701, A01716
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P866