Series: G110M

SI P1 (CU): SI Parameter copying rejected

converter

Meaning: The value 208 was saved or entered offline in p9700. An attempt is therefore made at start to copy the SI parameters from processor 1 to processor 2. However, no safety function is selected on processor 1 (p9601 = 0). The parameters therefore cannot be copied.

Possible causes

Source: SINAMICS G110M P688

Series: G115D, G120D

SI P1 (CU): SI Parameter copying rejected

converter

Meaning: The value 87 or 208 was saved in p9700 or entered offline. At start, an attempt is therefore made to copy the Safety Integrated parameters from processor 1 to processor 2. However, no safety function is selected on processor 1 (p9501 = 0, p9601 = 0). The parameters therefore cannot be copied.

Possible causes

Source: SINAMICS G115D P735; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P840

Series: G120-CU240B-E-2

SI P1: SI parameter copying rejected

converter

Meaning: The following value was saved in p9700 or entered offline: 87 or 208. Therefore, at start, an attempt is made to copy the SI parameters from processor 1 to processor 2. However, no safety functions are selected on processor 1 (p9501 = 0, p9601 = 0). Copying therefore cannot be performed. Note: This fault does not cause a safety stop reaction. See: p9700 (SI Copy function)

Possible causes

Source: SINAMICS G120 Control Unit CU240B_E-2 P650

Series: G120-CU250S-2

SI P1: SI parameter copying rejected

converter

Meaning: The following value has been saved in p9700 or entered offline: 87 or 208. Therefore, at start, an attempt is made to copy the SI parameters from processor 1 to processor 2. However, no safety functions are selected on processor 1 (p9501 = 0, p9601 = 0). Therefore, copying cannot be performed.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1323

Series: G120C, S120-S150

SI P1 (CU): SI Parameter copying rejected

converter

Meaning:

Possible causes

Source: SINAMICS G120C P662; SINAMICS S120_S150 P2592

Series: G130-G150

SI P1 (CU): SI Parameter copying rejected

converter

Meaning: The value 87 or 208 was saved in or entered offline in p9700. Therefore, at start, an attempt is made to copy the SI parameters from monitoring channel 1 to monitoring channel 2. However, no safety function is selected on monitoring channel 1 (p9501 = 0, p9601 = 0). Copying is rejected for safety reasons. This may cause a mismatch between the parameter settings in the two monitoring channels and trigger additional fault messages. In particular, if there is a mismatch in safety function enablement between the two monitoring channels (p9601 = 0, p9801 <> 0), fault F30625 is output.

Possible causes

Source: SINAMICS G130_G150 P1505

Series: S110

SI CU: SI Parameter copying rejected

servo drive

Meaning: The following values have been saved or entered offline in p9700: 87 or 208. Therefore, an attempt is made at start to copy the SI parameters from the control unit to the motor module. However, no safety functions have been selected on the control unit (p9501 = 0, p9601 = 0). The parameters therefore cannot be copied.

Possible causes

Source: SINAMICS S110 P962