Siemens F01625 fault code meaning
Siemens / F01625
Series: G115D
SI P1 (CU): Sign-of-life error in safety data
converter
Meaning: The drive-integrated "Safety Integrated" function on processor 1 detected an error in the safety data sign-of-life signal and triggered STOP A. - Communication between processors 1 and 2 was interrupted or faulty. - A time slice overflow occurred in the safety software.
Possible causes
Source: SINAMICS G115D P729
Series: G120-CU240B-E-2, G120-CU250S-2, G120C
Sign-of-life error in safety data
converter
Meaning:
Possible causes
Source: SINAMICS G120 Converter with Control Unit CU240E-2 P455; Converter SINAMICS G120 with Control Unit CU250S-2 P481; Converter SINAMICS G120C P403