Siemens F01600 fault code meaning
Siemens / F01600
Series: G115D
SI P1 (CU): STOP A triggered
converter
Meaning:
Possible causes
Source: SINAMICS G115D P725
Series: G120-CU240B-E-2
SI P1 (CU): STOP A triggered
converter
Meaning: The drive-integrated "Safety Integrated" function detected a fault in processor 1 and triggered STOP A. - The forced fault check of the safety shutdown circuit in processor 1 failed. Subsequent response of -F01611 (monitoring channel error).
Possible causes
Source: SINAMICS G120, Control Unit CU240B-2_CU240E-2 P702
Series: G120-CU250S-2
SI P1: STOP A triggered
converter
Meaning: The drive-integrated "Safety Integrated" function detected a fault in processor 1 and triggered STOP A. - The forced fault check of the safety shutdown circuit in processor 1 failed. Subsequent response of -F01611 (monitoring channel error).
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1314
Series: G130-G150
SI P1 (CU): STOP A triggered
converter
Meaning: The drive-integrated function "Safety Integrated" on the control unit (CU) has detected a fault and triggered STOP A (STO is triggered by an open circuit in Safety of the control unit). - The forced fault check of Safety on the control unit failed. Subsequent reaction of -F01611 (monitoring channel error).
Possible causes
Source: SINAMICS G130_G150 P1484
Series: S210
SI P1: STO triggered
servo drive
Meaning: A fault was detected in monitoring channel 1 of the drive-integrated "Safety Integrated" function, triggering STO. - The forced dormant fault check of the safety shutdown path in monitoring channel 1 failed. Subsequent response to -F01611 (monitoring channel error).
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P844