Siemens F01512 fault code meaning

Siemens / F01512

Series: DCM-6RA80

BICO: No scaling

DC drive

Meaning: An attempt was made to determine a conversion factor that has not yet been scaled.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P977

Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, G120D, G120X, G120XA, G130-G150, S120-S150

BICO: No scaling

converter

Meaning: An attempt was made to determine a conversion factor that has not yet been scaled.

Possible causes

Source: SINAMICS G110M P677; SINAMICS G115D P724; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P701; SINAMICS G120, Control Unit CU250S-2 P1313; SINAMICS G120C P652; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P829; SINAMICS G120X Converter P1360; SINAMICS G120XA PN Converter P1275; SINAMICS G130_G150 P1482; SINAMICS S120_S150 P2559

Series: G120-CU230P-2

An attempt was made to determine the conversion factor, but no setting was made

converter

Meaning:

Possible causes

Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P491

Series: G120P-Cabinet

An attempt was made to determine the conversion factor, but no

converter

Meaning:

Possible causes

Source: SINAMICS G120P Cabinet P508

Series: S110

BICO: No scaling

servo drive

Meaning: An attempt was made to determine a conversion factor that has not yet been scaled.

Possible causes