Siemens F01511 fault code meaning

Siemens / F01511

Series: DCM-6RA80

BICO: Connection has different scaling

DC drive

Meaning: The required BICO connection has already been established, but conversion using reference values is required between the BICO output and the BICO input. - The scaling units of the BICO output and the BICO input differ. - No error is reported for connections within a single drive object. Example: The scaling unit of the BICO output is "voltage", while that of the BICO input is "current". A conversion factor of p2002/p2001 is used between the BICO output and the BICO input. p2002: Reference value containing "current". p2001: Reference value containing "voltage".

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P977

Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, G120D, G130-G150, S120-S150

BICO: Connection has different scaling

converter

Meaning: The required BICO connection has been established, but conversion using reference values is required between the BICO output and the BICO input. - The scaling units of the BICO output and the BICO input differ. - No error is reported for connections within a single drive object. Example: The scaling unit of the BICO output is "voltage", while that of the BICO input is "current". Conversion between the BICO output and the BICO input uses the factor p2002/p2001. p2002: Reference value for "current". p2001: Reference value for "voltage".

Possible causes

Source: SINAMICS G110M P676; SINAMICS G115D P724; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P701; SINAMICS G120, Control Unit CU250S-2 P1313; SINAMICS G120C P651; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P828; SINAMICS G130_G150 P1482; SINAMICS S120_S150 P2559

Series: G120X, G120XA

BICO: Connection has different scaling

converter

Meaning: The required BICO connection has already been established, but conversion using reference values is required between the BICO output and the BICO input. - The scaling units of the BICO output and the BICO input differ. - No error is reported for connections within a single drive object. Example: The scaling unit of the BICO output is "voltage", while that of the BICO input is "current". A conversion factor of p2002/p2001 is used between the BICO output and the BICO input. p2002: Reference value containing "current". p2001: Reference value containing "voltage".

Possible causes

Source: SINAMICS G120X converter P1359; SINAMICS G120XA PN converter P1274

Series: S110

BICO: Connection has different scaling

servo drive

Meaning: The required BICO connection has been established, but conversion using reference values is required between the BICO output and the BICO input. - The scaling units of the BICO output and the BICO input differ. - No error is reported for connections within a single drive object. Example: The scaling unit of the BICO output is "voltage", while that of the BICO input is "current". Conversion between the BICO output and the BICO input uses the factor p2002/p2001. p2002: Reference value for "current". p2001: Reference value for "voltage".

Possible causes

Source: SINAMICS S110 P949