Siemens F01356 fault code meaning
Siemens / F01356
Series: DCM-6RA80
Topology: Damaged DRIVE-CLiQ component present
DC drive
Meaning: %1, Component number: %2, Interface number: %3 Message class: Hardware/software fault (1) Drive object: All objects Component: None Broadcast: LOCAL Response: None (OFF2) Acknowledgment: Immediate
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P959
Series: G120-CU250S-2
Topology: Damaged DRIVE-CLiQ component present
converter
Meaning: %1, component number: %2, interface number: %3. Drive object: All objects. Reaction: OFF2. Acknowledgment: Immediate.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1299
Series: G130-G150, S120-S150
Topology: Damaged DRIVE-CLiQ component present
converter
Meaning: %1, component number: %2, interface number: %3 Message class: Hardware/software fault (1) Drive object: All objects Component: None Broadcast: LOCAL Reaction: None (OFF2) Acknowledgment: Immediate
Possible causes
Source: SINAMICS G130_G150 P1463; SINAMICS S120_S150 P2540
Series: G200, G220
Topology: Damaged DRIVE-CLiQ component present
converter
Meaning:
Possible causes
Source: SINAMICS G200 Converter P625; SINAMICS G220 Converter P1199
Series: G210, G210X
Topology: Damaged DRIVE-CLiQ component present
converter
Meaning: %1, Component number: %2, Interface number: %3 Component: None Broadcast: Local Reaction: None (OFF2) Acknowledgment: Immediate Cause: At least one DRIVE-CLiQ component in the actual topology is damaged.
Possible causes
Source: SINAMICS G210 converter P999; SINAMICS G210X converter P866
Series: S110
Topology: Component damaged in the actual topology
servo drive
Meaning: %1, component number: %2, connection number: %3. Drive object: All objects. Reaction: OFF2. Acknowledgment: Immediate. Cause: At least one DRIVE-CLiQ component in the actual topology is damaged.
Possible causes
Source: SINAMICS S110 P942
Series: S200
Topology: Damaged component present
servo drive
Meaning: %1, Component number: %2, Interface number: %3 Component: None Reaction: None Acknowledgment: Immediate Cause: At least one faulty component is present in the actual topology. Note: Pulse enable is withdrawn and inhibited.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P465
Series: S220
Topology: Damaged DRIVE-CLiQ component present
converter
Meaning: %1, Component number: %2, Interface number: %3 Component: None Broadcast: Local Response: None (OFF2) Acknowledgment: Immediate Faults and alarms 5.5 List of faults and alarms SINAMICS S220 Converter 2088 Parameter Manual, 08/2026, FW V6.7, A5E53307549F AB
Possible causes
Source: SINAMICS S220 converter P2090