Siemens F01325 fault code meaning

Siemens / F01325

Series: DCM-6RA80

Topology: Component number not included in the configured topology

DC drive

Meaning: The components configured in parameters (e.g., p0121, p0131) are not included in the set topology.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P954

Series: G120-CU250S-2, G130-G150, S120-S150

Topology: Component number not included in the configured topology

converter

Meaning: The components configured in parameters (e.g., p0121, p0131) are not included in the set topology.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1296; SINAMICS G130_G150 P1459; SINAMICS S120_S150 P2536

Series: G200, G210, G210X, G220, S220

Topology: Component not included in the set topology

converter

Meaning: A component configured in a data set is not included in the configured topology.

Possible causes

Source: SINAMICS G200 converter P623; SINAMICS G210 converter P996; SINAMICS G210X converter P863; SINAMICS G220 converter P1197; SINAMICS S220 converter P2086

Series: S110

Topology: Component number not included in the configured topology

servo drive

Meaning: The components configured in parameters (e.g., p0121, p0131) are not included in the set topology.

Possible causes

Source: SINAMICS S110 P939

Series: S200

Topology: Component not included in the set topology

servo drive

Meaning: A component configured in a data set is not included in the configured topology.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P464