Siemens F01034 fault code meaning
Siemens / F01034
Series: DCM-6RA80
Unit conversion: Parameter value calculation failure after reference value change
DC drive
Meaning: The reference parameter change means that the set value cannot be recalculated according to %. The change is rejected and the initial value is restored.
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P929
Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120X, G120XA, G130-G150, S120-S150
Unit conversion: Parameter value calculation failure after reference value change
converter
Meaning: The reference parameter change means that the set value cannot be recalculated according to %. The change is rejected and the initial value is restored.
Possible causes
Source: SINAMICS G110M P667; SINAMICS G115D P714; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P692; SINAMICS G120, Control Unit CU250S-2 P1277; SINAMICS G120X Converter P1349; SINAMICS G120XA PN Converter P1264; SINAMICS G130_G150 P1433; SINAMICS S120_S150 P2508
Series: G120-CU230P-2
Unit changeover: After modifying the reference parameter
converter
Meaning:
Possible causes
Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P490
Series: G120C, G120D
Unit conversion: Parameter value calculation failure after reference value change
converter
Meaning:
Possible causes
Source: SINAMICS G120C P641; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P818
Series: G120P-Cabinet
Unit switching: After modifying the reference parameters
converter
Meaning:
Possible causes
Source: SINAMICS G120P Cabinet P509
Series: G200, G210, G210X, G220
Unit switching: Parameter value calculation failure after reference value change
converter
Meaning: The change to the reference parameter prevents the set value from being recalculated according to %. The change was rejected and the parameter was restored to its initial value.
Possible causes
Source: SINAMICS G200 Basic Converter P481; SINAMICS G210 Converter P978; SINAMICS G210X Converter P846; SINAMICS G220 Converter P1180
Series: S110
Unit conversion: Parameter value calculation failure after reference value change
servo drive
Meaning: The reference parameter change means that the set value cannot be recalculated according to %. The change is rejected and the initial value is restored.
Possible causes
Source: SINAMICS S110 P925
Series: S200, S210
Unit switching: Parameter value calculation failure after reference value change
servo drive
Meaning: The change to the reference parameter prevents the set value from being recalculated according to %. The change was rejected and the parameter was restored to its initial value.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P449; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1259