Siemens F01005 fault code meaning
Siemens / F01005
Series: DCM-6RA80
Firmware download failure for component DRIVE-CLiQ
DC drive
Meaning: %2 Message class: Hardware/software fault (1) Drive object: All objects Component: None Broadcast: LOCAL Response: None Acknowledgment: Immediate
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P923
Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, G120D
File upload/download failure
converter
Meaning: Upload or download of EEPROM data failed.
Possible causes
Source: SINAMICS G110M P663; SINAMICS G115D P710; SINAMICS G120 Control Unit CU240B- 2_CU240E- 2 P789; SINAMICS G120 Control Units CU250S-2 P982; SINAMICS G120C P638; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P815
Series: G120X, G120XA
File upload/download failure
converter
Meaning: Upload or download of EEPROM data failed.
Possible causes
Source: SINAMICS G120X converter P1346; SINAMICS G120XA PN converter P1261
Series: G130-G150, S120-S150
Firmware download failure for component DRIVE-CLiQ
converter
Meaning: %2 Message class: Hardware/software fault (1) Drive object: All objects Component: None Broadcast: LOCAL Reaction: None Acknowledgment: Immediate
Possible causes
Source: SINAMICS G130_G150 P1426; SINAMICS S120_S150 P2501
Series: S210
Firmware download failure for component DRIVE-CLiQ
servo drive
Meaning: %2 Component: None Broadcast: Local Response: None Faults and alarms 18.2 List of faults and alarms SINAMICS S210 Servo Drive System with SIMOTICS S-1FK2 and S-1FT2 1252 Operating Instructions, 05/2025, FW V6.4, A5E52380168F AF
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1254