Siemens A7469 fault code meaning

Siemens / A7469

Series: V90

EPOS: Traversing block < target position < negative software limit switch

servo drive

Meaning: Message category: Parameter setting/configuration/commissioning error (18). The absolute target position specified in the traversing block is outside the range defined by the negative software limit switch. Correct the traversing block.

Possible causes

Source: SINAMICS V90 PROFINET, SIMOTICS S-1FL6 Operating Instructions P393