Siemens A50514 fault code meaning

Siemens / A50514

Series: S110

FBLOCKS: Incorrect sampling time for the fixed execution cycle group

servo drive

Meaning: The configured system function sampling times (p0112, p0115) are too small, below the minimum sampling time (1 ms) permitted for the fixed execution cycle group of this system module. At least one module is assigned to the corresponding fixed execution cycle group.

Possible causes

Source: SINAMICS S110 P1182