Siemens A50513 fault code meaning
Siemens / A50513
Series: G110M, G115D, G120-CU240B-E-2, G120C, G120D
FBLOCKS: Sequence value has been set
converter
Meaning: An attempt was made to assign a sequence value already assigned to a function block on a drive object to another function block on the same drive object. A sequence value can be assigned to only one function block on a drive object.
Possible causes
Source: SINAMICS G110M P757; SINAMICS G115D P817; SINAMICS G120, control unit CU240B-2_CU240E-2 P798; SINAMICS G120C P726; SINAMICS G120D control unit CU240D- 2_CU250D- 2 P957
Series: G120X, G120XA
FBLOCKS: Sequence value has been set
converter
Meaning: An attempt was made to assign a sequence value already assigned to one function block on a drive object to another function block on the same drive object. A sequence value can only be assigned to one function block on a drive object.
Possible causes
Source: SINAMICS G120X converter P1421; SINAMICS G120XA PN converter P1330
Series: S110
FBLOCKS: Sequence value has been set
servo drive
Meaning: An attempt was made to assign a sequence value already assigned to a function block on a drive object to another function block on the same drive object. A sequence value can be assigned to only one function block on a drive object.
Possible causes
Source: SINAMICS S110 P1182