Siemens A50006 fault code meaning

Siemens / A50006

Series: DCM-6RA80

Communication board: warning 6

DC drive

Meaning: CBE20 SINAMICS Link: Reception of telegrams sent by the device itself has been configured. This setting is not permitted.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1205

Series: G130-G150

Communication board: warning 6

converter

Meaning:

Possible causes

Source: SINAMICS G130_G150 P2014

Series: S120-S150

Reception of its own send data is configured. This is not permitted.

converter

Meaning:

Possible causes

Source: SINAMICS S120 Function Manual: Communication P220