Siemens A49204 fault code meaning

Siemens / A49204

Series: G130-G150, S120-S150

Field disabled alarm

converter

Meaning: When the field is disabled, the field current has still not decayed after the delay time (p1647) has elapsed.

Possible causes

Source: SINAMICS G130_G150 P2012; SINAMICS S120_S150 P3229