Siemens A38433 fault code meaning
Siemens / A38433
Series: S220
AIM: Power supply reactor core temperature exceeded the alarm threshold
converter
Meaning: The line reactor core temperature (r4566[1]) measured by the Active Interface Module (Active Interface Module, abbreviated as AIM) has exceeded the threshold.
Possible causes
Source: SINAMICS S220 converter P2753