Siemens A35226 fault code meaning
Siemens / A35226
Series: S120-S150
TM: Signal A/B not active
converter
Meaning: No frequency setpoint is available for Terminal Module 41 (TM41). The A/B signal output has been frozen. Possible causes: - Analog interconnection input p4420 is not interconnected. - The master encoder is not in the "ready" status (encoder parked or encoder data set not parameterized). - A fault is present at TM41. - TM41 is in commissioning mode (p0010 > 0). - Component TM41 is not connected to DRIVE-CLiQ.
Possible causes
Source: SINAMICS S120_S150 P3158
Series: S220
TM: A/B code track not activated
converter
Meaning: No frequency setpoint is available for terminal module 41 (TM41). The output of the A/B track has been frozen. Possible causes: - Digital signal sink c4420 is not interconnected. - The master encoder is not in the "Ready" status (encoder parked or encoder data set parameters not configured). - A fault is present on TM41. - TM41 is in commissioning mode. - Component TM41 is not connected to DRIVE-CLiQ.
Possible causes
Source: SINAMICS S220 converter P2689