Siemens A35081 fault code meaning
Siemens / A35081
Series: G130-G150, S120-S150
TM54F: Steady-state 1 signal present on F-DI for safety acknowledgment
converter
Meaning: The logic 1 signal remains present for more than 10 seconds at F-DI configured in p10006. If no acknowledgment is given at F-DI for safety acknowledgment, a static logic 0 signal must be present. This prevents unintended safety acknowledgment (or the "Internal event acknowledgment" signal) in the event of an open circuit or vibration at either of the two digital inputs.
Possible causes
Source: SINAMICS G130_G150 P1958; SINAMICS S120_S150 P3149