Siemens A33811 fault code meaning
Siemens / A33811
Series: G120-CU250S-2
Encoder 3: Encoder serial number has changed
converter
Meaning: The encoder serial number has changed. Only encoders with serial numbers (e.g., EnDat encoders) are checked for changes. - Encoder replacement.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1578
Series: G130-G150, S120-S150
Encoder 3: Encoder serial number changed
converter
Meaning: The encoder serial number has changed. Only encoders with serial numbers (e.g., EnDat encoders) are checked for changes. - Encoder replacement.
Possible causes
Source: SINAMICS G130_G150 P1918;SINAMICS S120_S150 P3109
Series: G210
Encoder 3: Encoder serial number has changed
converter
Meaning: The encoder serial number has changed. This check applies only to encoders with a serial number (for example, EnDat encoders). - The encoder has been replaced. Note: With position control, the serial number is transferred when calibration starts (p2507 = 2). After encoder calibration is complete (p2507 = 3), the serial number is checked for changes.
Possible causes
Source: SINAMICS G210 converter P1344