Siemens A33700 fault code meaning
Siemens / A33700
Series: DCM-6RA80
Encoder 3: Validity test did not produce the expected value
DC drive
Meaning: %1 bin Message class: Safety monitoring channel detected a fault (10) Drive object: DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S Component: Sensor Module encoder 3 Broadcast: GLOBAL Response: None Acknowledgment: None Cause: DRIVE-CLiQ The encoder fault word indicates a set fault bit.
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1157
Series: G120-CU250S-2
Encoder 3: Validity test did not produce the expected value
converter
Meaning: %1 bin Drive object: CU250S_S, CU250S_S_CAN, CU250S_S_DP, CU250S_S_PN. Reaction: None. Acknowledgment: None. Cause: DRIVE-CLiQ The encoder fault word reports fault bits that have been set.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1575
Series: G130-G150
Encoder 3: Validity test did not produce the expected value
converter
Meaning: %1 bin Message class: Safety monitoring channel detected a fault (10) Drive object: VECTOR_G Component: Sensor Module encoder 3 Broadcast: GLOBAL Reaction: None Acknowledgment: None Cause: The fault word of encoder DRIVE-CLiQ reports set fault bits.
Possible causes
Source: SINAMICS G130_G150 P1915
Series: G210
Encoder 3: Validity test did not produce the expected value
converter
Meaning: %1 bin Component: Encoder module 3 Response: None. Acknowledgment: None. Cause: The fault word of the DRIVE-CLiQ encoder reports set fault bits.
Possible causes
Source: SINAMICS G210 converter P1341
Series: S120-S150
Encoder 3: Validity test did not produce the expected value
converter
Meaning: %1 bin Message class: Safety monitoring channel detected a fault (10) Drive object: HLA, SERVO, SERVO_AC, SERVO_I_AC, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Sensor Module encoder 3 Broadcast: GLOBAL Response: None Acknowledgment: None Cause: The fault word of the DRIVE-CLiQ encoder reports a set fault bit.
Possible causes
Source: SINAMICS S120_S150 P3105