Siemens A32432 fault code meaning
Siemens / A32432
Series: G120-CU250S-2
Encoder 2: Rotor position adaptation error
converter
Meaning: Pulses on signal A/B have been lost or counted multiple times. The compensation curve for these pulses is a straight line.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1555
Series: S110
Encoder 2: Rotor position adaptation error
servo drive
Meaning: Pulses on signal A/B have been lost or counted multiple times. The compensation curve for these pulses is a straight line.
Possible causes
Source: SINAMICS S110 P1165
Series: S120-S150
Encoder 2: Rotor position alignment correction error
converter
Meaning: Pulses on signal A/B have been lost or counted multiple times. The compensation curve for these pulses is a straight line.
Possible causes
Source: SINAMICS S120_S150 P3051