Encoder 2: Signal A or B out of tolerance

converter

Meaning: The amplitude/phase/offset compensation for signal A or signal B has reached its limit. Amplitude error compensation: amplitude B/ amplitude A = 0.78 ... 1.27. Phase: <84 degrees or >96 degrees. SMC20: deviation compensation: +/-140mV. SMC10: deviation compensation: +/-650mV.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1082

Series: G130-G150

Encoder 2: Track A or B outside the tolerance rang

converter

Meaning:

Possible causes

Source: G150 P957

Series: S110

Encoder 2: Signal A or B out of tolerance

servo drive

Meaning: The amplitude/phase/offset compensation for signal A or signal B has reached its limit. Amplitude error compensation: amplitude B/ amplitude A = 0.78 ... 1.27. Phase: <84 degrees or >96 degrees. SMC20: deviation compensation: +/-140mV. SMC10: deviation compensation: +/-650mV.

Possible causes