Siemens A32410 fault code meaning
Siemens / A32410
Series: G120-CU250S-2, G120D
Encoder 2: Serial communication
converter
Meaning: An error occurred during serial communication record transmission between the encoder and the signal conversion module.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1130; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P951
Series: S110
Encoder 2: Serial communication
servo drive
Meaning: %1 bin Drive object: SERVO_S110-CAN, SERVO_S110-DP, SERVO_S110-PN Reaction: None. Acknowledgment: None. Cause: Error in serial communication record transfer between the encoder and the signal conversion module.
Possible causes
Source: SINAMICS S110 P1160
Series: S120-S150
Encoder 2: Communication fault (encoder and encoder module
converter
Meaning: %1 bin Message class: Position/speed actual value incorrect or missing (11) Drive object: HLA, SERVO, SERVO_AC, SERVO_I_AC, VECTOR, VECTOR_AC, VECTOR_I_AC Component: Encoder 2 Broadcast: LOCAL Response: None Acknowledgment: None
Possible causes
Source: SINAMICS S120_S150 P3045