Siemens A31463 fault code meaning

Siemens / A31463

Series: DCM-6RA80

Encoder 1: Analog sensor position value exceeds the limit

DC drive

Meaning: The position value exceeded the permissible range: 0.5 ... +0.5.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1089

Series: G120-CU240B-E-2, G120-CU250S-2, G130-G150, S120-S150

Encoder 1: Analog sensor position value exceeds the limit

converter

Meaning: The position value exceeded the permissible range: 0.5 ... +0.5.

Possible causes

Source: SINAMICS G120, Control Unit CU240B-2_CU240E-2 P788; SINAMICS G120, Control Unit CU250S-2 P1518; SINAMICS G130_G150 P1816; SINAMICS S120_S150 P3000

Series: G210

Motor encoder: Analog sensor position value exceeded the limit

converter

Meaning:

Possible causes

Source: SINAMICS G210 converter P1256

Series: S110

Encoder 1: Analog sensor position value exceeds the limit

servo drive

Meaning: The position value exceeded the permissible range: 0.5 ... +0.5.

Possible causes

Source: SINAMICS S110 P1132

Series: S220

Motor encoder: Analog sensor position value exceeded the limit

converter

Meaning: The position value exceeded the permissible range: 0.5 ... +0.5.

Possible causes

Source: SINAMICS S220 converter P2538