Siemens A31460 fault code meaning

Siemens / A31460

Series: DCM-6RA80

Encoder 1: Analog encoder channel A fault

DC drive

Meaning: The analog encoder input voltage exceeded the permissible limits.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1088

Series: G120-CU240B-E-2, G120-CU250S-2

Encoder 1: Analog encoder channel A fault

converter

Meaning: The analog encoder input voltage exceeded the permissible limits.

Possible causes

Source: SINAMICS G120, Control Unit CU240B-2_CU240E-2 P787; SINAMICS G120, Control Unit CU250S-2 P1517

Series: S110

Encoder 1: Analog encoder channel A fault

servo drive

Meaning: The analog encoder input voltage exceeded the permissible limits.

Possible causes

Source: SINAMICS S110 P1131

Series: S120-S150

Encoder 1: Analog encoder channel A fault

converter

Meaning:

Possible causes

Source: SINAMICS S120_S150 P2998