Siemens A31421 fault code meaning
Siemens / A31421
Series: DCM-6RA80
Encoder 1: Measured commutation position error (alarm
DC drive
Meaning: A fault was detected during actual value detection for the commutation position.
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1085
Series: G120-CU250S-2
Encoder 1: Coarse position error
converter
Meaning: A fault was detected during actual value acquisition. This fault indicates that actual value acquisition supplied an incorrect coarse position.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1515