Siemens A30709 fault code meaning

Siemens / A30709

Series: S210

SI motion P2: SS2E triggered

servo drive

Meaning: SS2E stops the drive (braking along the trajectory). After the set delay has elapsed, "Safe Operating Stop" (SOS) is activated. Possible causes: Subsequent response to the following messages: A30714, A30716 See also: p9553 (SI transition time from motion SS2E to SOS)

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 P533