Siemens A30666 fault code meaning

Siemens / A30666

Series: G115D, G120-CU240B-E-2, G120-CU250S-2, G120D, G130-G150, S120-S150

SI motion P2: A logic 1 signal is continuously present on F-DI for safety acknowledgment

converter

Meaning: The logic 1 signal at F-DI configured in p10106 has persisted for more than 10 seconds. If no acknowledgment is issued at F-DI for safety acknowledgment, a static logic 0 signal must be present. This prevents unintended safety acknowledgment (or the "Internal event acknowledgment" signal) if an open circuit occurs or either of the two digital inputs chatters.

Possible causes

Source: SINAMICS G115D P808; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P777; SINAMICS G120, Control Unit CU250S-2 P1033; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P930; SINAMICS G130_G150 P1753; SINAMICS S120_S150 P2928

Series: S110

SI motion MM: Static 1 signal for the safety response on F-DI

servo drive

Meaning: The logic 1 signal at F-DI configured in p10106 has persisted for more than 10 seconds. If no acknowledgment is issued at F-DI for safety acknowledgment, a static logic 0 signal must be present. This prevents unintended safety acknowledgment (or the "Internal event acknowledgment" signal) if an open circuit occurs or either of the two digital inputs chatters.

Possible causes

Source: SINAMICS S110 P1097