Siemens A30044 fault code meaning

Siemens / A30044

Series: DCM-6RA80

Power unit: 24/48 V Overvoltage alarm

DC drive

Meaning: The power supply to the power unit exceeded the upper threshold limit.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1046

Series: G120-CU250S-2

Power unit: 24/48 V Overvoltage alarm

converter

Meaning: The power supply to the power unit exceeded the upper threshold limit.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1466

Series: G130-G150, S120-S150

Power unit: 24V overvoltage alarm

converter

Meaning: The power supply to the power unit exceeded the upper threshold limit.

Possible causes

Source: SINAMICS G130_G150 P1729; SINAMICS S120_S150 P2897

Series: G200, G210, G210X, G220

Power unit: 24 V overvoltage alarm

converter

Meaning: The power supply to the power unit exceeds the upper threshold limit.

Possible causes

Source: SINAMICS G200 converter P759; SINAMICS G210 converter P1199; SINAMICS G210X converter P1025; SINAMICS G220 converter P1458

Series: S110

Power unit: 24V overvoltage alarm

servo drive

Meaning: Applies to CU31x: Power unit 24 V power supply fault. - Threshold 32.0 V exceeded.

Possible causes

Source: SINAMICS S110 P1082

Series: S210

Power unit: 24/48 V overvoltage alarm

servo drive

Meaning: The power supply to the power unit exceeds the upper threshold limit.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1359

Series: S220

Power unit: 24/48 V overvoltage alarm

converter

Meaning: The power supply to the power unit exceeds the upper threshold limit.

Possible causes

Source: SINAMICS S220 Converter P2470