Siemens A30010 fault code meaning
Siemens / A30010
Series: DCM-6RA80
Power unit: Cyclic data sign-of-life error
DC drive
Meaning: DRIVE-CLiQ A communication fault has occurred between the control unit and the associated power unit. The power unit failed to receive the cyclic setpoint telegram from the control unit on time for at least one cycle.
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1036
Series: G120-CU250S-2, G130-G150
Power unit: Cyclic data sign-of-life error
converter
Meaning: DRIVE-CLiQ A communication fault has occurred between the control unit and the associated power unit. The power unit failed to receive the cyclic setpoint telegram from the control unit on time for at least one cycle.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1454; SINAMICS G130_G150 P1715
Series: G200
Power unit: Cyclic data sign-of-life error
converter
Meaning: An internal communication error occurred in the converter. The converter's cyclic setpoint telegram was not received on time for at least one cycle.
Possible causes
Source: SINAMICS G200 Basic converter P622
Series: G210, G210X
Power unit: Cyclic data heartbeat signal error
converter
Meaning:
Possible causes
Source: SINAMICS G210 converter P1186; SINAMICS G210X converter P1012
Series: G220
Power unit: Cyclic data heartbeat signal error
converter
Meaning: An internal communication error occurred in the converter. The converter's cyclic setpoint telegram was not received on time for at least one cycle.
Possible causes
Source: SINAMICS G220 Converter P1444
Series: S220
Power unit: Cyclic data heartbeat signal error
converter
Meaning: DRIVE-CLiQ communication error between the control unit and the associated power unit. The power unit did not receive the cyclic setpoint telegram from the control unit on time for at least one cycle.