Siemens A08565 fault code meaning
Siemens / A08565
Series: G110M, G115D, G120-CU240B-E-2, G120C, G120X
PROFINET: Parameter setting consistency error
converter
Meaning: A consistency error was detected when activating the configuration (p8925) of the PROFINET interface. The currently set configuration has not been activated.
Possible causes
Source: SINAMICS G110M P728; SINAMICS G115D P786; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P754; SINAMICS G120C P698; SINAMICS G120X Converter P1400
Series: G120-CU230P-2
Consistency error affects adjustable parameters
converter
Meaning:
Possible causes
Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P495
Series: G120-CU250S-2
CBE20: Parameter setting consistency error
converter
Meaning: A consistency error was detected when activating the configuration (p8945 = 1) for Communication Board Ethernet 20 (CBE20). The currently set configuration was not activated. Possible causes: - The IP address, subnet mask, or default gateway is incorrect. - Duplicate IP address or station name in the network. - The station name contains invalid characters, etc.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1443
Series: G120D, G120XA
PROFINET: Parameter setting consistency error
converter
Meaning:
Possible causes
Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P910; SINAMICS G120XA PN Converter P1310
Series: G120P-Cabinet
PROFINET: Consistency of parameter settings
converter
Meaning:
Possible causes
Source: SINAMICS G120P Cabinet P513
Series: G130-G150
PN/COMM BOARD: Consistency error in parameter settings
converter
Meaning: A consistency error was detected while activating the configuration (p8945) for Ethernet communication board 20/25/41 (CBE20/CBE25/CBE41).
Possible causes
Source: SINAMICS G130_G150 P1701
Series: S110
PROFINET: Parameter setting consistency error
servo drive
Meaning: A consistency error was detected when activating the PROFINET interface configuration (p8925 = 1). The currently set configuration was not activated. Possible causes: - Incorrect IP address, subnet mask, or default gateway. - Duplicate IP address or station name on the network. - The station name contains invalid characters, etc. See: p8920 (PROFINET station name), p8921 (PN IP station address), p8922 (PN station default gateway), p8923 (PN station subnet mask).
Possible causes
Source: SINAMICS S110 P1067