Siemens A08560 fault code meaning

Siemens / A08560

Series: G130-G150, S120-S150

IE: Configuration file syntax error

converter

Meaning: A syntax error was detected in the ASCII configuration file for the Industrial Ethernet interface (X127). The saved configuration was not loaded.

Possible causes

Source: SINAMICS G130_G150 P1699; SINAMICS S120_S150 P2864

Series: G200, G210, G210X, G220, S220

IE: Configuration file syntax error

converter

Meaning: A syntax error was detected in the configuration file for the Industrial Ethernet interface (X127). The saved configuration was not loaded. Note: IE: Industrial Ethernet (Industrial Ethernet).

Possible causes

Source: SINAMICS G200 converter P740; SINAMICS G210 converter P1179; SINAMICS G210X converter P1005; SINAMICS G220 converter P1400; SINAMICS S220 converter P2401

Series: S200

IE: Configuration file syntax error

servo drive

Meaning: A syntax error was detected in the configuration file for the Industrial Ethernet interface (X127). The saved configuration was not loaded. Note: IE: Industrial Ethernet (Industrial Ethernet).

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P545