Siemens A07980 fault code meaning
Siemens / A07980
Series: G110M, G115D, G120-CU230P-2, G120D
Rotating measurement active
converter
Meaning:
Possible causes
Source: SINAMICS G110M Converter P380; SINAMICS G115D Wall-mounted Converter P414; Converter SINAMICS G120, with Control Unit CU230P-2 P495; Converter SINAMICS G120D, with Control Unit CU250D-2 P330
Series: G120-CU240B-E-2, G120X, G120XA, G130-G150, S120-S150
Drive: Rotation detection active
converter
Meaning: Rotating measurement (auto optimization of the speed loop) is activated. Rotating measurement will be performed with the next switch-on command.
Possible causes
Source: SINAMICS G120, Control Unit CU240B-2_CU240E-2 P749; SINAMICS G120X Converter P1394; SINAMICS G120XA PN Converter P1305; SINAMICS G130_G150 P1687; SINAMICS S120_S150 P2842
Series: G120-CU250S-2
Drive: Rotation detection active
converter
Meaning: Rotating measurement is active. During rotating measurement, the motor accelerates to the maximum speed and reaches the maximum torque. Only the current limit setting (p0640) and maximum speed (p1082) are valid. Motor behavior can be controlled using direction inhibits (p1959.14, p1959.15) and ramp-up/ramp-down times (p1958). Rotating measurement will be performed at the next switch-on command. See: p1960 (Rotating measurement selection).
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1428
Series: G120C, G120P-Cabinet
Rotating motor data detection is active.
converter
Meaning:
Possible causes
Source: Converter SINAMICS G120C P406; SINAMICS G120P Cabinet P513
Series: G200, G210, G220
Drive: Rotation detection active
converter
Meaning: Rotating measurement (auto tuning of the speed controller) is activated. Rotating measurement will be performed on the next switch-on command. Note: Parameters must not be saved during rotating measurement (p0977). See also: p1960 (Rotating measurement selection).
Possible causes
Source: SINAMICS G200 Basic converter P608; SINAMICS G210 converter P1171; SINAMICS G220 converter P1392
Series: G210X
Drive: Rotation detection active
converter
Meaning:
Possible causes
Source: SINAMICS G210X Converter P997
Series: S110
Drive: Rotation detection active
servo drive
Meaning: Rotating measurement is active. During rotating measurement, the motor accelerates to the maximum speed and reaches the maximum torque. Only the current limit setting (p0640) and maximum speed (p1082) are valid. Motor behavior can be controlled using direction inhibits (p1959.14, p1959.15) and ramp-up/ramp-down times (p1958). Rotating measurement will be performed at the next switch-on command. See: p1960 (Rotating measurement selection).
Possible causes
Source: SINAMICS S110 P1059
Series: S220
Drive: Rotation detection active
converter
Meaning: Rotating measurement is activated. During rotating measurement, the motor accelerates to maximum speed and reaches maximum torque. Only the set current limit (p0640) and maximum speed (p1082) are valid. Motor behavior can be controlled using direction inhibition (p1959.14, p1959.15) and ramp-up/ramp-down times (p1958). Rotating measurement is performed upon the next switch-on command. See also: p1960
Possible causes
Source: SINAMICS S220 converter P2383