Siemens A07932 fault code meaning
Siemens / A07932
Series: G130-G150, S120-S150
Holding brake does not apply
converter
Meaning: An alarm is output when r1229.5 = 1. When r1229.5 = 1, OFF1/OFF3 is suppressed to prevent the drive from accelerating under the load; OFF 2 remain valid. See also: p1217 (Motor holding brake application time), r1229 (Motor holding brake status word).
Possible causes
Source: SINAMICS G130_G150 P1675; SINAMICS S120_S150 P2828
Series: G210X
Holding brake does not apply
converter
Meaning: An alarm is output when r1229.5 = 1. When r1229.5 = 1, OFF1/OFF3 is suppressed to prevent the drive from accelerating under the influence of the load; OFF2 remains valid. See also: p1217 (Motor holding brake application time). Faults and alarms 5.2 List of faults and alarms SINAMICS G210X Converter 988 Parameter Manual, 07/2026, FW V6.7, A5E54375466F AA
Possible causes
Source: SINAMICS G210X converter P990
Series: S110
Holding brake does not apply
servo drive
Meaning: The alarm is output when r1229.5 = 1. When r1229.5 = 1, OFF1/OFF3 is suppressed to prevent the drive from accelerating under the load; OFF 2 remains valid. See: p1217 (Motor holding brake application time), r1229 (Motor holding brake status word).
Possible causes
Source: SINAMICS S110 P1057