Siemens A07598 fault code meaning

Siemens / A07598

Series: G130-G150

Encoder 3: Referencing function interruption

converter

Meaning: The active referencing function (reference pulse search or measuring probe evaluation) has been interrupted. - An encoder fault has occurred (Gn_ZSW.15 = 1). - The actual position value was set while the referencing function was active. - Reference mark search and measuring probe evaluation were activated simultaneously (Bl:p2508 and Bl:p2509 = 1 signal). - The active referencing function (reference mark search or measuring probe evaluation) was canceled (Bl:p2508 and Bl:p2509 = 0 signal).

Possible causes

Source: SINAMICS G130_G150 P1653