Siemens A07597 fault code meaning
Siemens / A07597
Series: G120-CU250S-2, G120D, G130-G150
Encoder 2: Referencing function interruption
converter
Meaning: The active referencing function (reference pulse search or measuring probe evaluation) has been interrupted. - An encoder fault has occurred (Gn_ZSW.15 = 1). - The actual position value was set while the referencing function was active. - Reference mark search and measuring probe evaluation were activated simultaneously (Bl:p2508 and Bl:p2509 = 1 signal). - The active referencing function (reference mark search or measuring probe evaluation) was canceled (Bl:p2508 and Bl:p2509 = 0 signal).
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1407; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P889; SINAMICS G130_G150 P1653
Series: S110
Encoder 2: Referencing function interruption
servo drive
Meaning: The active referencing function (reference pulse search or measuring probe evaluation) has been interrupted. - An encoder fault has occurred (Gn_ZSW.15 = 1). - The actual position value was set while the referencing function was active. - Reference mark search and measuring probe evaluation were activated simultaneously (Bl:p2508 and Bl:p2509 = 1 signal). - The active referencing function (reference mark search or measuring probe evaluation) was canceled (Bl:p2508 and Bl:p2509 = 0 signal).
Possible causes
Source: SINAMICS S110 P1044
Series: S120-S150
Encoder 2: Referencing function interruption
converter
Meaning:
Possible causes
Source: SINAMICS S120_S150 P2799
Series: S200
Encoder 2: Reference point return function interruption
servo drive
Meaning: The active reference point approach procedure (zero pulse search or probe evaluation) was interrupted. - An encoder error occurred (Gn_ZSW.15 = 1). - The actual position value was set while the reference point approach function was active. - Zero pulse search and probe evaluation were activated simultaneously. - The active reference point approach procedure (zero pulse search or probe evaluation) was inhibited.
Possible causes
Source: SINAMICS S200 Spindle Drive P401
Series: S210
Encoder 2: Reference point return function interruption
servo drive
Meaning: The active homing procedure (reference mark search or probe evaluation) was interrupted. - An encoder fault occurred (Gn_ZSW.15 = 1). - The actual position value was set while the homing function was active. - Reference mark search and probe evaluation were activated simultaneously (c2508 and c2509 = 1 signal). - The active homing procedure (reference mark search or probe evaluation) was inhibited (c2508 and c2509 = 0 signal).
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1339