Siemens A07586 fault code meaning
Siemens / A07586
Series: G130-G150, S120-S150
Encoder 3: Activate position setting value
converter
Meaning: When binector input p2514 = 1, the actual position is set to the value received via connector input p2515. Any control deviation that may be present cannot be corrected.
Possible causes
Source: SINAMICS G130_G150 P1650; SINAMICS S120_S150 P2796
Series: S220
Encoder 3: Activate position setting value
converter
Meaning: When binector input c2514 outputs signal 1, the actual position value is set to the value obtained from digital signal input c2515. Any control deviation that may exist cannot be eliminated.
Possible causes
Source: SINAMICS S220 Converter P2338