Siemens A07584 fault code meaning
Siemens / A07584
Series: G120-CU250S-2, G120D
Encoder 1: Position setting value activated
converter
Meaning: When the signal is BI: p2514 = 1, the actual position value is set to the value obtained via CI: p2515. Any existing control deviation cannot be compensated.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1404; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P888
Series: G130-G150, S120-S150
Encoder 1: Position setting value activated
converter
Meaning: When binector input p2514 = 1, the actual position is set to the value received via connector input p2515. Any control deviation that may be present cannot be corrected.
Possible causes
Source: SINAMICS G130_G150 P1649; SINAMICS S120_S150 P2796
Series: S110
Encoder 1: Position setting value activated
servo drive
Meaning: When the signal is BI: p2514 = 1, the actual position value is set to the value obtained via CI: p2515. Any existing control deviation cannot be compensated.
Possible causes
Source: SINAMICS S110 P1042
Series: S220
Motor encoder: Position setting value activated
converter
Meaning: When binector input c2514 outputs signal 1, the actual position value is set to the value obtained from digital signal input c2515. Any control deviation that may exist cannot be eliminated.
Possible causes
Source: SINAMICS S220 Converter P2337