Siemens A07530 fault code meaning
Siemens / A07530
Series: DCM-6RA80
Drive: Drive data set DDS does not exist
DC drive
Meaning:
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P1014
Series: G110M, G120-CU240B-E-2, G120-CU250S-2
Drive: Drive data set DDS does not exist
converter
Meaning: The selected drive data set does not exist (p0837 > p0180). Drive data set changeover was not performed. See: p0180 (Number of drive data sets (DDS)), p0820 (Drive data set selection DDS bit 0), p0821 (Drive data set selection DDS bit 1), r0837 (Select drive data set DDS)
Possible causes
Source: SINAMICS G110M P710; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P739; SINAMICS G120, Control Unit CU250S-2 P1397
Series: G115D
Drive: Drive data set DDS does not exist
converter
Meaning: The selected drive data set does not exist (p0837 > p0180). Drive data set changeover was not performed. See also: p0180 (Number of drive data sets (DDS)), p0820 (Drive data set selection DDS bit 0), p0821 (Drive data set selection DDS bit 1), r0837 (Select drive data set DDS).
Possible causes
Source: SINAMICS G115D P768
Series: G120C
Drive: Drive data set DDS does not exist
converter
Meaning: The selected drive data set does not exist. Drive data set changeover was not performed. See also: p0180 (Number of drive data sets (DDS)), p0820 (Drive data set selection DDS, bit 0), r0837 (Select drive data set DDS)
Possible causes
Source: SINAMICS G120C P683
Series: G120D
Drive: Drive data set DDS does not exist
converter
Meaning:
Possible causes
Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P883
Series: G120X, G120XA, G130-G150, S120-S150
Drive: Drive data set DDS does not exist
converter
Meaning: The selected drive data set does not exist (p0837 > p0180). Drive data set changeover was not performed. See also: p0180, p0820, p0821, p0822, p0823, p0824, r0837
Possible causes
Source: SINAMICS G120X Converter P1383; SINAMICS G120XA Converter Operating Instructions P935; SINAMICS G130_G150 P1638; SINAMICS S120_S150 P2783
Series: G200
Drive: Drive data set DDS does not exist
converter
Meaning: The selected drive data set does not exist (r0837 > p0180). The drive data set was not switched. See also: p0180, c0820, c0821, r0837
Possible causes
Source: SINAMICS G200 Converter P717
Series: G210, G210X
Drive: Drive data set DDS does not exist
converter
Meaning: The selected drive data set does not exist (r0837 > p0180). Drive data set changeover was not performed. See also: p0180 (Number of drive data sets (DDS)), c0820 (Drive data set selection DDS bit 0), c0821 (Drive data set selection DDS bit 1), r0837 (Select drive data set DDS)
Possible causes
Source: SINAMICS G210 converter P1135; SINAMICS G210X converter P977
Series: G220
Drive: Drive data set DDS does not exist
converter
Meaning: The selected drive data set does not exist (r0837 > p0180). Drive data set switching was not performed. See also: p0180, c0820, c0821, c0822, c0823, r0837
Possible causes
Source: SINAMICS G220 converter P1352
Series: S110
Drive: Drive data set DDS does not exist
servo drive
Meaning: The selected drive data set does not exist (p0837 > p0180). The drive data set changeover was not performed. See: p0180 (Number of drive data sets (DDS)), p0820 (Drive data set selection DDS bit 0), r0837 (Drive data set selection DDS).
Possible causes
Source: SINAMICS S110 P1034
Series: S210
Drive: Drive data set DDS does not exist
servo drive
Meaning:
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1335
Series: S220
Drive: Drive data set DDS does not exist
converter
Meaning: The selected drive data set does not exist (r0837 > p0180). Drive data set changeover was not performed. See also: p0180, c0820, c0821, c0822, c0823, c0824, r0837
Possible causes
Source: SINAMICS S220 Converter P2323