Siemens A07519 fault code meaning
Siemens / A07519
Series: G130-G150, S120-S150
Drive: Incorrect parameter setting for motor switching
converter
Meaning: Motor changeover is performed by the application program by setting p0833.0 = 1. Therefore, p0827 must have different values in the respective motor data sets.
Possible causes
Source: SINAMICS G130_G150 P1638; SINAMICS S120_S150 P2782
Series: S110
Drive: Incorrect parameter setting for motor switching
servo drive
Meaning: Motor changeover is performed by the application program by setting p0833.0 = 1. Therefore, p0827 must have different values in the respective motor data sets.
Possible causes
Source: SINAMICS S110 P1034
Series: S220
Drive: Incorrect parameter settings for motor changeover
converter
Meaning:
Possible causes
Source: SINAMICS S220 converter P2322