Siemens A07514 fault code meaning

Siemens / A07514

Series: G120-CU250S-2

Drive: Data structure does not match interface mode

converter

Meaning: Interface mode "SIMODRIVE 611U" is set (p2038 = 1), but the data structure does not match this mode. Depending on the number of data sets, the following settings are possible: Number of DDS/MDS (p0180/p0130): p0186 1/1: p0186[0] = 0 2/2: p0186[0] = 0, p0186[1] = 1

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1395

Series: S110

Drive: Data structure does not match interface mode

servo drive

Meaning: Interface mode "SIMODRIVE 611U" (p2038 = 1) is set, but the data structure does not match this mode. The following rules must be observed in this data structure: Within each group of 8 drive data sets, the motor data set assignments must be identical: p0186[0] = p0186[1] = ... = p0186[7] p0186[8] = p0186[9] = ... = p0186[15] p0186[16] = p0186[17] = ... = p0186[23] p0186[24] = p0186[25] = ... = p0186[31]. See: p0180 (Number of drive data sets (DDS)), p0186 (Motor data set (MDS) number), p2038 (IF1 PROFIdrive STW/ZSW interface mode).

Possible causes

Source: SINAMICS S110 P1033