Siemens A07506 fault code meaning

Siemens / A07506

Series: G130-G150, S120-S150

EPOS: Check the BICO interconnection between EPOS and the position loop

converter

Meaning: Although the BICO interconnection for transmitting the fine resolution has been configured, the BICO interconnection for transmitting the reference between EPOS and LR has not been configured.

Possible causes

Source: SINAMICS G130_G150 P1634;SINAMICS S120_S150 P2778