Siemens A07497 fault code meaning

Siemens / A07497

Series: G120-CU250S-2, G120D

Position loop: Position setpoint activated

converter

Meaning: When the signal is BI: p2514 = 1, the actual position value is set to the value obtained via CI: p2515. Any existing control deviation cannot be compensated.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1392; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P882

Series: G130-G150, S120-S150

Position loop: Position setpoint activated

converter

Meaning: When binector input p2514 = 1, the actual position is set to the value received via connector input p2515. Any control deviation that may be present cannot be corrected.

Possible causes

Source: SINAMICS G130_G150 P1631;SINAMICS S120_S150 P2775

Series: S110

Position loop: Position setpoint activated

servo drive

Meaning: When the signal is BI: p2514 = 1, the actual position value is set to the value obtained via CI: p2515. Any existing control deviation cannot be compensated.

Possible causes

Source: SINAMICS S110 P1030

Series: S220

Position loop: Position setpoint activated

converter

Meaning: When binector input c2514 outputs signal 1, the actual position value is set to the value obtained from digital signal sink c2515. Any existing control deviation cannot be eliminated.

Possible causes

Source: SINAMICS S220 converter P2316