Siemens A07495 fault code meaning

Siemens / A07495

Series: G120-CU250S-2

Position loop: Referencing function interruption

converter

Meaning: Interruption of the active referencing function (reference pulse search or measuring probe evaluation). Possible causes: - An encoder fault has occurred (Gn_ZSW.15 = 1). - The actual position value is set while the referencing function is active. - Reference mark search and measuring probe evaluation are activated simultaneously (Bl:p2508 and Bl:p2509 = 1 signal). - The active referencing function (reference mark search or measuring probe evaluation) is canceled (Bl:p2508 and Bl:p2509 = 0 signal).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1392

Series: G120D

Position loop: Referencing function interruption

converter

Meaning: Interruption of the active referencing function (reference pulse search or measuring probe evaluation). Possible causes: - An encoder fault has occurred (Gn_ZSW.15 = 1). - The actual position value was set while the referencing function was active. - Reference mark search and measuring probe evaluation were activated simultaneously (Bl:p2508 and Bl:p2509 = 1 signal). - The active referencing function (reference mark search or measuring probe evaluation) was canceled (Bl:p2508 and Bl:p2509 = 0 signal). - The measuring probe input terminal has not been configured.

Possible causes

Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P882

Series: G130-G150

LR: Reference function interrupted

converter

Meaning:

Possible causes

Source: G150 P872

Series: G210

Position loop: Referencing function interruption

converter

Meaning: Interruption of the active referencing procedure (zero pulse search or probe evaluation). Possible causes: - An encoder error occurred (Gn_ZSW.15 = 1). - The actual position value was set while the referencing function was active. - Zero pulse search and probe evaluation were activated simultaneously. - The active referencing procedure (zero pulse search or probe evaluation) was inhibited. - The probe input terminal has not been configured.

Possible causes

Source: SINAMICS G210 converter P1130

Series: S110

Position loop: Referencing function interruption

servo drive

Meaning: The active referencing function (reference pulse search or measuring probe evaluation) has been interrupted. - An encoder fault has occurred (Gn_ZSW.15 = 1). - The actual position value was set while the referencing function was active. - Reference mark search and measuring probe evaluation were activated simultaneously (Bl:p2508 and Bl:p2509 = 1 signal). - The active referencing function (reference mark search or measuring probe evaluation) was canceled (Bl:p2508 and Bl:p2509 = 0 signal).

Possible causes

Source: SINAMICS S110 P1029

Series: S200

Position loop: Referencing function interruption

servo drive

Meaning: The active reference point approach procedure (zero pulse search or probe evaluation) was interrupted. Possible causes: - An encoder error occurred (Gn_ZSW.15 = 1). - The actual position value was set while the reference point approach function was active. - Zero pulse search and probe evaluation were activated simultaneously. - The active reference point approach procedure (zero pulse search or probe evaluation) was inhibited.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P534

Series: S210

Position loop: Referencing function interruption

servo drive

Meaning: The active homing procedure (reference mark search or probe evaluation) was interrupted. Possible causes: - An encoder fault occurred (Gn_ZSW.15 = 1). - The actual position value was set while the homing function was active. - Reference mark search and probe evaluation were activated simultaneously. - The active homing procedure (reference mark search or probe evaluation) was inhibited.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1334