Siemens A07483 fault code meaning

Siemens / A07483

Series: G120-CU250S-2, G120D, G130-G150, S120-S150

EPOS: Clamping torque not reached when traveling to a fixed stop

converter

Meaning: The fixed stop in the traversing block has been reached without the clamping torque/clamping force being reached.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1389; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P879; SINAMICS G130_G150 P1627; SINAMICS S120_S150 P2771

Series: G210, G220, S220

EPOS: Clamping torque not reached when traveling to a fixed stop

converter

Meaning: The fixed stop in the traversing block has been reached without reaching the clamping torque or clamping force.

Possible causes

Source: SINAMICS G210 converter P1126; SINAMICS G220 converter P1343; SINAMICS S220 converter P2311

Series: S110

EPOS: Clamping torque not reached when traveling to a fixed stop

servo drive

Meaning: The fixed stop in the traversing block has been reached without the clamping torque/clamping force being reached.

Possible causes

Source: SINAMICS S110 P1026

Series: S200, S210

EPOS: Clamping torque not reached when traveling to a fixed stop

servo drive

Meaning: The fixed stop in the traversing block has been reached without reaching the clamping torque or clamping force.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P531; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1331