Siemens A07479 fault code meaning
Siemens / A07479
Series: G120-CU250S-2, G120D, G130-G150, S120-S150
EPOS: Approaching negative software limit switch
converter
Meaning: The axis is at the negative software limit switch position. The active traversing block has been interrupted.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1388; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P879; SINAMICS G130_G150 P1626; SINAMICS S120_S150 P2770
Series: G210, G220, S220
EPOS: Negative software limit switch reached
converter
Meaning: The axis is at the negative software limit switch position. The active traversing block has been interrupted.
Possible causes
Source: SINAMICS G210 converter P1125; SINAMICS G220 converter P1342; SINAMICS S220 converter P2310
Series: S110
EPOS: Approaching negative software limit switch
servo drive
Meaning: The axis is at the negative software limit switch position. The active traversing block has been interrupted.
Possible causes
Source: SINAMICS S110 P1025
Series: S200, S210
EPOS: Negative software limit switch reached
servo drive
Meaning: The axis is at the negative software limit switch position. The active traversing block has been interrupted.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P530; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1330