Siemens A07466 fault code meaning

Siemens / A07466

Series: G120-CU250S-2, G120D, G130-G150, G210, G220, S120-S150, S220

EPOS: Traversing block number assigned multiple times

converter

Meaning: The same traversing block number has been assigned more than once.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1386; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P877; SINAMICS G130_G150 P1623; SINAMICS G210 Converter P1122; SINAMICS G220 Converter P1339; SINAMICS S120_S150 P2767; SINAMICS S220 Converter P2306

Series: S110, S200, S210

EPOS: Traversing block number assigned multiple times

servo drive

Meaning: The same traversing block number has been assigned more than once.

Possible causes