Siemens A07462 fault code meaning

Siemens / A07462

Series: G120-CU250S-2, G120D, G130-G150, S120-S150

EPOS: Selected traversing block number does not exist

converter

Meaning: The traversing block selected via BI: p2625 ... p2630 is started by the 0/1 pulse edge of BI: p2631, "Activate traversing task". - The number of the started traversing block is not included in p2616[0...n]. - The started traversing block is hidden.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1385; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P876; SINAMICS G130_G150 P1622; SINAMICS S120_S150 P2766

Series: G210, G220, S220

EPOS: Selected traversing block number does not exist

converter

Meaning: The traversing block selected via binector inputs c2625 ... c2630 is started by the pulse edge at binector input c2631 = 0/1, "Activate traversing task". - The number of the started traversing block is not included in p2616[0...n]. - The started traversing block is hidden.

Possible causes

Source: SINAMICS G210 converter P1121; SINAMICS G220 converter P1338; SINAMICS S220 converter P2305

Series: S110

EPOS: Selected traversing block number does not exist

servo drive

Meaning: The traversing block selected via BI: p2625 to BI: p2630 is started by the "Activate traversing task" pulse edge at BI: p2631 = 0/1. - The number of the started traversing block is not included in p2616[0...n]. - The started traversing block is hidden.

Possible causes

Source: SINAMICS S110 P1022

Series: S200, S210

EPOS: Selected traversing block number does not exist

servo drive

Meaning: The traversing block selected via c2625 ... c2629 is started by the edge of binary signal c2631 = 0/1 "Activate traversing task". - The number of the started traversing block is not included in p2616[0...n]. - The started traversing block is hidden.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P526; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1326