Siemens A07441 fault code meaning

Siemens / A07441

Series: G120-CU250S-2

Position loop: Back up the position offset for absolute encoder adjustment

converter

Meaning: The absolute encoder adjustment status has changed. To retain the detected position offset (p2525) permanently, it must be saved to nonvolatile storage (p0971).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1380

Series: G120D

Position loop: Back up the position offset for absolute encoder adjustment

converter

Meaning: The absolute encoder adjustment status has changed. To permanently accept the detected position offset (p2525), it must be saved in nonvolatile storage (p0971).

Possible causes

Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P873

Series: G130-G150, S120-S150

Position loop: Back up the position offset for absolute encoder adjustment

converter

Meaning: The absolute encoder adjustment status has changed. Nonvolatile storage (p0971, p0977) is required to permanently retain the detected position offset (p2525) and drive data set number (p2733). Possible causes: - The motor or encoder has been replaced (applies to EQN and DQI). - Position-related parameters have changed. - An uncalibrated encoder has been calibrated (using the "Copy from RAM to ROM" nonvolatile storage item).

Possible causes

Source: SINAMICS G130_G150 P1616;SINAMICS S120_S150 P2760

Series: G210

Position loop: Back up the position offset for absolute encoder calibration

converter

Meaning:

Possible causes

Source: SINAMICS G210 converter P1113

Series: G220

Position loop: Back up the position offset for absolute encoder calibration

converter

Meaning: The absolute encoder calibration status has changed. To permanently apply the detected position offset and drive data set number, save the parameters in nonvolatile memory (p0977). Possible causes: - The motor or encoder has been replaced (applies to EQN and DQI). - Parameters related to the forward direction have changed. - An uncalibrated encoder has been calibrated (project saved in nonvolatile memory). Note: Provided that the configurable monitoring window has not been exited, previous axis motion will not trigger this message after power-on.

Possible causes

Source: SINAMICS G220 Converter P1331

Series: S110

Position loop: Back up the position offset for absolute encoder adjustment

servo drive

Meaning: The absolute encoder adjustment status has changed. Nonvolatile storage (p0971, p0977) is required to retain the detected position offset (p2525) permanently.

Possible causes

Source: SINAMICS S110 P1017

Series: S200

Position loop: Back up the position offset for absolute encoder calibration

servo drive

Meaning: The absolute encoder calibration status has changed. To apply the detected position offset permanently, save the parameters in nonvolatile memory (p0977). Possible causes: - The motor or encoder has been replaced (applies to EQN and DQI). - Position-related parameters have changed. - An uncalibrated encoder has been calibrated (project saved in nonvolatile memory). Note: Provided that the configurable monitoring window has not been exited, previous axis movement will not trigger this message after power-on again. System messages 11.3 Faults and alarms SINAMICS S200 pulse train input servo drive system with SIMOTICS S-1FL2 500 Operating Instructions, 06/2026, FW V6.7, A5E51646767F AF

Possible causes

Source: SINAMICS S200 Pulse train input_SIMOTICS S-1FL2 P502

Series: S210

Position loop: Back up the position offset for absolute encoder calibration

servo drive

Meaning:

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1321

Series: S220

Position loop: Back up the position offset for absolute encoder calibration

converter

Meaning: The absolute encoder calibration status has changed. To permanently apply the detected position offset (p2525) and drive data set number (p2733), save the parameters in nonvolatile memory (p0977). Possible causes: - The motor or encoder has been replaced (applies to EQN and DQI). - Parameters related to the forward direction have changed. - An uncalibrated encoder has been calibrated (project saved in nonvolatile memory). Note: As long as the axis has not left the configurable monitoring window, previous axis movements will not cause this message after power-on again.

Possible causes

Source: SINAMICS S220 converter P2297