Siemens A07402 fault code meaning

Siemens / A07402

Series: G110M

Drive: Minimum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller has been activated because the voltage has fallen below the lower activation threshold (r1246, r1286). The motor's kinetic energy is used to support the DC bus. This brakes the drive. See: r0056 (Closed-loop control status word), p1240 (Vdc controller configuration (vector control)), p1280 (Vdc control or Vdc monitoring configuration (V/f))

Possible causes

Source: SINAMICS G110M P707

Series: G115D

Drive: Minimum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller has been activated because the voltage fell below the lower activation threshold (r1246, r1286). The motor's kinetic energy is used to support the DC bus. This brakes the drive. See also: r0056 (Closed-loop control status word), p1240 (Vdc controller configuration (vector control)), p1280 (Vdc control or Vdc monitoring configuration (V/f)).

Possible causes

Source: SINAMICS G115D P765

Series: G120-CU240B-E-2, G120C

Drive: Minimum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller has been activated because the voltage fell below the lower activation threshold (r1246, r1286). The motor's kinetic energy is used to support the DC bus. This brakes the drive. See also: r0056 (Closed-loop control status word), p1240 (Vdc Controller configuration (vector control)), p1280 (Vdc Controller configuration (V/f))

Possible causes

Source: SINAMICS G120 Control Unit CU240B- 2_CU240E- 2 P842; SINAMICS G120C P681

Series: G120-CU250S-2

Drive: Minimum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller has been activated because the voltage has fallen below the lower switch-on threshold (r1246, r1286). The motor's kinetic energy is used to support the DC bus voltage, causing the drive to brake. See: r0056 (Closed-loop control status word), p1240 (Vdc controller configuration (vector control)), p1280 (Vdc controller configuration (V/f))

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P971

Series: G120X

Drive: Minimum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller is activated because the voltage has fallen below the lower activation threshold (r1246, r1286). The motor's kinetic energy is used to support the DC bus voltage. This brakes the drive. See also: r0056, p1240, p1280

Possible causes

Source: SINAMICS G120X Converter P1379

Series: G120XA

Drive: Minimum DC bus voltage controller active

converter

Meaning:

Possible causes

Source: SINAMICS G120XA PN converter P1289

Series: G130-G150, S120-S150

Drive: Minimum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller has been activated because the voltage has fallen below the lower activation threshold (r1246, r1286). The motor's kinetic energy is used to support the DC bus, thereby braking the drive. See also: r0056 (Closed-loop control status word), p1240 (Vdc control or Vdc monitoring configuration), p1280 (Vdc control or Vdc monitoring configuration (V/f))

Possible causes

Source: SINAMICS G130_G150 P1609;SINAMICS S120_S150 P2745

Series: G200, G210, G210X, G220, S220

Drive: Minimum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller was activated because the voltage fell below the lower activation threshold (r1246, r1286). The motor's kinetic energy is used to sustain the DC bus. This brakes the drive. See also: r0056 (closed-loop control status word), p1240 (Vdc control or Vdc monitoring configuration), p1280 (Vdc control or Vdc monitoring configuration (V/f))

Possible causes

Source: SINAMICS G200 Converter P709; SINAMICS G210 Converter P1107; SINAMICS G210X Converter P968; SINAMICS G220 Converter P1324; SINAMICS S220 Converter P2280

Series: S110

Drive: Minimum DC bus voltage controller active

servo drive

Meaning: The DC bus voltage controller was activated because the voltage fell below the lower activation threshold (p1248). This results in a control deviation between the reference speed and the actual speed. This may be caused by a fault in the power supply system. See: r0056 (Closed-loop control status word), p1240 (Vdc control or Vdc monitoring configuration), p1248 (DC bus voltage lower limit).

Possible causes

Source: SINAMICS S110 P1011